System Function Blocks | SFB | 0 | CTU | IEC_TC | Count Up |
System Function Blocks | SFB | 1 | CTD | IEC_TC | Count Down |
System Function Blocks | SFB | 2 | CTUD | IEC_TC | Count Up/Down |
System Function Blocks | SFB | 3 | TP | IEC_TC | Generate a Pulse |
System Function Blocks | SFB | 4 | TON | IEC_TC | Generate an On Delay |
System Function Blocks | SFB | 5 | TOF | IEC_TC | Generate an Off Delay |
System Function Blocks | SFB | 8 | USEND | COM_FUNC | Uncoordinated Sending of Data |
System Function Blocks | SFB | 9 | URCV | COM_FUNC | Uncoordinated Receiving of Data |
System Function Blocks | SFB | 12 | BSEND | COM_FUNC | Sending Segmented Data |
System Function Blocks | SFB | 13 | BRCV | COM_FUNC | Receiving Segmented Data |
System Function Blocks | SFB | 14 | GET | COM_FUNC | Read Data from a Remote CPU |
System Function Blocks | SFB | 15 | PUT | COM_FUNC | Write Data to a Remote CPU |
System Function Blocks | SFB | 16 | COM_FUNC | Send Data to Printer | |
System Function Blocks | SFB | 19 | START | COM_FUNC | Initiate a Warm or Cold Restart on a Remote Device |
System Function Blocks | SFB | 20 | STOP | COM_FUNC | Changing a Remote Device to the STOP State |
System Function Blocks | SFB | 21 | RESUME | COM_FUNC | Initiate a Hot Restart on a Remote Device |
System Function Blocks | SFB | 22 | STATUS | COM_FUNC | Query the Status of a Remote Partner |
System Function Blocks | SFB | 23 | USTATUS | COM_FUNC | Receive the Status of a Remote Device |
System Function Blocks | SFB | 29 | HS_COUNT | COUNTERS | Counter (high-speed counter, integrated function) (only exist on the CPU 312 IFM and CPU 314 IFM) |
System Function Blocks | SFB | 30 | FREQ_MES | COUNTERS | Frequency Meter (frequency meter, integrated function (only exist on the CPU 312 IFM and CPU 314 IFM) |
System Function Blocks | SFB | 31 | NOTIFY_8P | COM_FUNC | Generating block related messages without acknowledgement indication |
System Function Blocks | SFB | 32 | DRUM | TIMERS | Implement a Sequencer |
System Function Blocks | SFB | 33 | ALARM | COM_FUNC | Generate Block-Related Messages with Acknowledgment Display |
System Function Blocks | SFB | 34 | ALARM_8 | COM_FUNC | Generate Block-Related Messages without Values for 8 Signals |
System Function Blocks | SFB | 35 | ALARM_8P | COM_FUNC | Generate Block-Related Messages with Values for 8 Signals |
System Function Blocks | SFB | 36 | NOTIFY | COM_FUNC | Generate Block-Related Messages without Acknowledgment Display |
System Function Blocks | SFB | 37 | AR_SEND | COM_FUNC | Send Archive Data |
System Function Blocks | SFB | 38 | HSC_A_B | COUNTERS | Counter A/B (integrated function) (only exist on the CPU 314 IFM) |
System Function Blocks | SFB | 39 | POS | ICONT | Position (integrated function) (only exist on the CPU 314 IFM) |
System Function Blocks | SFB | 41 | CONT_C | ICONT | Continuous Control (only exist on the CPU 314 IFM) |
System Function Blocks | SFB | 42 | CONT_S | ICONT | Step Control (only exist on the CPU 314 IFM) |
System Function Blocks | SFB | 43 | PULSEGEN | ICONT | Pulse Generation (only exist on the CPU 314 IFM) |
System Function Blocks | SFB | 44 | ANALOG | TEC_FUNC | Positioning with Analog Output (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 46 | DIGITAL | TEC_FUNC | Positioning with Digital Output (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 47 | COUNT | TEC_FUNC | Controlling the Counter (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 48 | FREQUENC | TEC_FUNC | Controlling the Frequency Measurement (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 49 | PULSE | TEC_FUNC | Controlling Pulse Width Modulation (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 52 | RDREC | DP | Reading a Data Record |
System Function Blocks | SFB | 53 | WRREC | DP | Writing a Data Record |
System Function Blocks | SFB | 54 | RALRM | DP | Receiving an Interrupt |
System Function Blocks | SFB | 60 | SEND_PTP | TEC_FUNC | Sending Data (ASCII, 3964(R)) (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 61 | RECV_PTP | TEC_FUNC | Receiving Data (ASCII, 3964(R)) (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 62 | RES_RECV | TEC_FUNC | Deleting the Receive Buffer (ASCII, 3964(R)) (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 63 | SEND_RK | TEC_FUNC | Sending Data (RK 512) (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 64 | FETCH_RK | TEC_FUNC | Fetching Data (RK 512) (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 65 | SERVE_RK | TEC_FUNC | Receiving and Providing Data (RK 512) (only exist on the S7-300C CPUs) |
System Function Blocks | SFB | 75 | SALRM | DP | Send interrupt to DP master |
System Function Blocks | SFB | 81 | RD_DPAR | IO_FUNCT | Read Predefined Parameter |
System Function Blocks | SFC | 0 | SET_CLK | CLK_FUNC | Set System Clock |
System Function Blocks | SFC | 1 | READ_CLK | CLK_FUNC | Read System Clock |
System Function Blocks | SFC | 2 | SET_RTM | CLK_FUNC | Set Run-time Meter |
System Function Blocks | SFC | 3 | CTRL_RTM | CLK_FUNC | Start/Stop Run-time Meter |
System Function Blocks | SFC | 4 | READ_RTM | CLK_FUNC | Read Run-time Meter |
System Function Blocks | SFC | 5 | GADR_LGC | IO_FUNCT | Query Logical Address of a Channel |
System Function Blocks | SFC | 6 | RD_SINFO | DB_FUNCT | Read OB Start Information |
System Function Blocks | SFC | 7 | DP_PRAL | DP | Trigger a Hardware Interrupt on the DP Master |
System Function Blocks | SFC | 9 | EN_MSG | COM_FUNC | Enable Block-Related, Symbol-Related and Group Status Messages |
System Function Blocks | SFC | 10 | DIS_MSG | COM_FUNC | Disable Block-Related, Symbol-Related and Group Status Messages |
System Function Blocks | SFC | 11 | DPSYC_FR | DP | Synchronize Groups of DP Slaves |
System Function Blocks | SFC | 12 | D_ACT_DP | DP | Deactivation and activation of DP slaves |
System Function Blocks | SFC | 13 | DPNRM_DG | DIAGNSTC | Read Diagnostic Data of a DP Slave (Slave Diagnostics) |
System Function Blocks | SFC | 14 | DPRD_DAT | DP | Read Consistent Data of a Standard DP Slave |
System Function Blocks | SFC | 15 | DPWR_DAT | DP | Write Consistent Data to a DP Standard Slave |
System Function Blocks | SFC | 17 | ALARM_SQ | PMC_FUNC | Generate Acknowledgeable Block-Related Messages |
System Function Blocks | SFC | 18 | ALARM_S | PMC_FUNC | Generate Permanently Acknowledged Block-Related Messages |
System Function Blocks | SFC | 19 | ALARM_SC | PMC_FUNC | Query the Acknowledgment Status of the last ALARM_SQ Entering State Message |
System Function Blocks | SFC | 20 | BLKMOV | MOVE | Copy Variables |
System Function Blocks | SFC | 21 | FILL | MOVE | Initialize a Memory Area |
System Function Blocks | SFC | 22 | CREAT_DB | DB_FUNCT | Create Data Block |
System Function Blocks | SFC | 23 | DEL_DB | DB_FUNCT | Delete Data Block |
System Function Blocks | SFC | 24 | TEST_DB | DB_FUNCT | Test Data Block |
System Function Blocks | SFC | 25 | COMPRESS | DB_FUNCT | Compress the User Memory |
System Function Blocks | SFC | 26 | UPDAT_PI | IO_FUNCT | Update the Process Image Update Table |
System Function Blocks | SFC | 27 | UPDAT_PO | IO_FUNCT | Update the Process Image Output Table |
System Function Blocks | SFC | 28 | SET_TINT | PGM_CNTL | Set Time-of-Day Interrupt |
System Function Blocks | SFC | 29 | CAN_TINT | PGM_CNTL | Cancel Time-of-Day Interrupt |
System Function Blocks | SFC | 30 | ACT_TINT | PGM_CNTL | Activate Time-of-Day Interrupt |
System Function Blocks | SFC | 31 | QRY_TINT | PGM_CNTL | Query Time-of-Day Interrupt |
System Function Blocks | SFC | 32 | SRT_DINT | PGM_CNTL | Start Time-Delay Interrupt |
System Function Blocks | SFC | 33 | CAN_DINT | PGM_CNTL | Cancel Time-Delay Interrupt |
System Function Blocks | SFC | 34 | QRY_DINT | PGM_CNTL | Query Time-Delay Interrupt |
System Function Blocks | SFC | 35 | MP_ALM | PGM_CNTL | Trigger Multicomputing Interrupt |
System Function Blocks | SFC | 36 | MSK_FLT | DIAGNSTC | Mask Synchronous Errors |
System Function Blocks | SFC | 37 | DMSK_FLT | DIAGNSTC | Unmask Synchronous Errors |
System Function Blocks | SFC | 38 | READ_ERR | DIAGNSTC | Read Error Register |
System Function Blocks | SFC | 39 | DIS_IRT | IRT_FUNC | Disable New Interrupts and Asynchronous Errors |
System Function Blocks | SFC | 40 | EN_IRT | IRT_FUNC | Enable New Interrupts and Asynchronous Errors |
System Function Blocks | SFC | 41 | DIS_AIRT | IRT_FUNC | Delay Higher Priority Interrupts and Asynchronous Errors |
System Function Blocks | SFC | 42 | EN_AIRT | IRT_FUNC | Enable Higher Priority Interrupts and Asynchronous Errors |
System Function Blocks | SFC | 43 | RE_TRIGR | PGM_CNTL | Re-trigger Cycle Time Monitoring |
System Function Blocks | SFC | 44 | REPL_VAL | DIAGNSTC | Transfer Substitute Value to Accumulator 1 |
System Function Blocks | SFC | 46 | STP | PGM_CNTL | Change the CPU to STOP |
System Function Blocks | SFC | 47 | WAIT | PGM_CNTL | Delay Execution of the User Program |
System Function Blocks | SFC | 48 | SNC_RTCB | CLK_FUNC | Synchronize Slave Clocks |
System Function Blocks | SFC | 49 | LGC_GADR | IO_FUNCT | Query the Module Slot Belonging to a Logical Address |
System Function Blocks | SFC | 50 | RD_LGADR | IO_FUNCT | Query all Logical Addresses of a Module |
System Function Blocks | SFC | 51 | RDSYSST | DIAGNSTC | Read a System Status List or Partial List |
System Function Blocks | SFC | 52 | WR_USMSG | DIAGNSTC | Write a User-Defined Diagnostic Event to the Diagnostic Buffer |
System Function Blocks | SFC | 54 | RD_PARM | IO_FUNCT | Read Defined Parameters |
System Function Blocks | SFC | 55 | WR_PARM | IO_FUNCT | Write Dynamic Parameters |
System Function Blocks | SFC | 56 | WR_DPARM | IO_FUNCT | Write Default Parameters |
System Function Blocks | SFC | 57 | PARM_MOD | IO_FUNCT | Assign Parameters to a Module |
System Function Blocks | SFC | 58 | WR_REC | IO_FUNCT | Write a Data Record |
System Function Blocks | SFC | 59 | RD_REC | IO_FUNCT | Read a Data Record |
System Function Blocks | SFC | 60 | GD_SND | COM_FUNC | Send a GD Packet |
System Function Blocks | SFC | 61 | GD_RCV | COM_FUNC | Fetch a Received GD Packet |
System Function Blocks | SFC | 62 | CONTROL | COM_FUNC | Query the Status of a Connection Belonging to a Communication SFB Instance |
System Function Blocks | SFC | 63 | AB_CALL | PLASTICS | Assembly Code Block (only exists for CPU 614) |
System Function Blocks | SFC | 64 | TIME_TCK | CLK_FUNC | Read the System Time |
System Function Blocks | SFC | 65 | X_SEND | COM_FUNC | Send Data to a Communication Partner outside the Local S7 Station |
System Function Blocks | SFC | 66 | X_RCV | COM_FUNC | Receive Data from a Communication Partner outside the Local S7 Station |
System Function Blocks | SFC | 67 | X_GET | COM_FUNC | Read Data from a Communication Partner outside the Local S7 Station |
System Function Blocks | SFC | 68 | X_PUT | COM_FUNC | Write Data to a Communication Partner outside the Local S7 Station |
System Function Blocks | SFC | 69 | X_ABORT | COM_FUNC | Abort an Existing Connection to a Communication Partner outside the Local S7 Station |
System Function Blocks | SFC | 70 | GEO_LOG | IO_FUNCT | Determine Start Address of a Module |
System Function Blocks | SFC | 71 | LOG_GEO | IO_FUNCT | Determine the Slot Belonging to a Logical Address |
System Function Blocks | SFC | 72 | I_GET | COM_FUNC | Read Data from a Communication Partner within the Local S7 Station |
System Function Blocks | SFC | 73 | I_PUT | COM_FUNC | Write Data to a Communication Partner within the Local S7 Station |
System Function Blocks | SFC | 74 | I_ABORT | COM_FUNC | Abort an Existing Connection to a Communication Partner within the Local S7 Station |
System Function Blocks | SFC | 78 | OB_RT | DIAGNSTC | Determine OB program runtime |
System Function Blocks | SFC | 79 | SET | BIT_LOGC | Set a Range of Outputs |
System Function Blocks | SFC | 80 | RSET | BIT_LOGC | Reset a Range of Outputs |
System Function Blocks | SFC | 81 | UBLKMOV | MOVE | Uninterruptible Block Move |
System Function Blocks | SFC | 82 | CREA_DBL | DB_CTRL | Create a Data Block in the Load Memory |
System Function Blocks | SFC | 83 | READ_DBL | DB_CTRL | Read from a Data Block in Load Memory |
System Function Blocks | SFC | 84 | WRIT_DBL | DB_CTRL | Write from a Data Block in Load Memory |
System Function Blocks | SFC | 85 | CREA_DB | DB_FUNCT | Create a Data Block |
System Function Blocks | SFC | 87 | C_DIAG | COM_FUNC | Diagnosis of the Actual Connection Status |
System Function Blocks | SFC | 90 | H_CTRL | HF_FUNCT | Control Operation in H Systems |
System Function Blocks | SFC | 100 | SET_CLKS | CLK_FUNC | Setting the Time-of-Day and the TOD Status |
System Function Blocks | SFC | 101 | RTM | CLK_FUNC | Handling runtime meters |
System Function Blocks | SFC | 102 | RD_DPARA | IO_FUNCT | Redefined Parameters |
System Function Blocks | SFC | 103 | DP_TOPOL | DP | Identifying the bus topology in a DP master system |
System Function Blocks | SFC | 104 | CIR | PGM_CNTL | Controlling CiR |
System Function Blocks | SFC | 105 | READ_SI | PMC_FUNC | Reading Dynamic System Resources |
System Function Blocks | SFC | 106 | DEL_SI | PMC_FUNC | Deleting Dynamic System Resources |
System Function Blocks | SFC | 107 | ALARM_DQ | PMC_FUNC | Generating Always Acknowledgeable and Block-Related Messages |
System Function Blocks | SFC | 108 | ALARM_D | PMC_FUNC | Generating Always Acknowledgeable and Block-Related Messages |
System Function Blocks | SFC | 112 | PN_IN | PROFIne2 | Update inputs in the user program interface of PROFInet components |
System Function Blocks | SFC | 113 | PN_OUT | PROFIne2 | Update outputs in the user program interface of PROFInet components |
System Function Blocks | SFC | 114 | PN_DP | PROFIne2 | Update DP interconnections |
System Function Blocks | SFC | 126 | SYNC_PI | IO_FUNCT | Update process image partition input table in synchronous cycle |
System Function Blocks | SFC | 127 | SYNC_PO | IO_FUNCT | Update process image partition output table in synchronous cycle |
S5-S7 Converting Blocks | FC | 61 | GP_FPGP | S5_CNVRT | Change fixed point number to floating point number |
S5-S7 Converting Blocks | FC | 62 | GP_GPFP | S5_CNVRT | Change floating point number to fixed point number |
S5-S7 Converting Blocks | FC | 63 | GP_ADD | S5_CNVRT | Add floating point numbers |
S5-S7 Converting Blocks | FC | 64 | GP_SUB | S5_CNVRT | Subtract floating point numbers |
S5-S7 Converting Blocks | FC | 65 | GP_MUL | S5_CNVRT | Multiply floating point number |
S5-S7 Converting Blocks | FC | 66 | GP_DIV | S5_CNVRT | Divide floating point numbers |
S5-S7 Converting Blocks | FC | 67 | GP_VGL | S5_CNVRT | Compare floating point numbers |
S5-S7 Converting Blocks | FC | 68 | RAD_GP | S5_CNVRT | Extract root of floating point numbers |
S5-S7 Converting Blocks | FC | 69 | MLD_TG | S5_CNVRT | Clock generator |
S5-S7 Converting Blocks | FC | 70 | MLD_TGZ | S5_CNVRT | Clock generator (timing element) |
S5-S7 Converting Blocks | FC | 71 | MLD_EZW | S5_CNVRT | Message of first value with single flashing light, wordwise, A |
S5-S7 Converting Blocks | FC | 72 | MLD_EDW | S5_CNVRT | Message of first value with double flashing light, wordwise, A |
S5-S7 Converting Blocks | FC | 73 | MLD_SAMW | S5_CNVRT | Collected message, wordwise (sound alert) |
S5-S7 Converting Blocks | FC | 74 | MLD_SAM | S5_CNVRT | Collected message, bitwise |
S5-S7 Converting Blocks | FC | 75 | MLD_EZ | S5_CNVRT | Message of first value with single flashing light, bitwise, A |
S5-S7 Converting Blocks | FC | 78 | MLD_EDWK | S5_CNVRT | Message of first value with double flashing light, wordwise, A+M |
S5-S7 Converting Blocks | FC | 79 | MLD_EZK | S5_CNVRT | Message of first value with single flashing light, bitwise, A+M |
S5-S7 Converting Blocks | FC | 80 | MLD_EDK | S5_CNVRT | Message of first value with double flashing light, bitwise, A+M |
S5-S7 Converting Blocks | FC | 81 | COD_B4 | S5_CNVRT | Change BCD number to 16 bit dual number |
S5-S7 Converting Blocks | FC | 82 | COD_16 | S5_CNVRT | Change 16 bit dual number to BCD number |
S5-S7 Converting Blocks | FC | 83 | MUL_16 | S5_CNVRT | Multiply 16 bit dual numbers |
S5-S7 Converting Blocks | FC | 84 | DIV_16 | S5_CNVRT | Divide 16 bit dual numbers |
S5-S7 Converting Blocks | FC | 85 | ADD_32 | S5_CNVRT | Add 32 bit dual numbers |
S5-S7 Converting Blocks | FC | 86 | SUB_32 | S5_CNVRT | Subtract 32 bit dual numbers |
S5-S7 Converting Blocks | FC | 87 | MUL_32 | S5_CNVRT | Multiply 32 bit dual numbers |
S5-S7 Converting Blocks | FC | 88 | DIV_32 | S5_CNVRT | Divide 32 bit dual numbers |
S5-S7 Converting Blocks | FC | 89 | RAD_16 | S5_CNVRT | Extract roots of 16 bit dual numbers |
S5-S7 Converting Blocks | FC | 90 | REG_SCHB | S5_CNVRT | Bi-directional shift register, bitwise |
S5-S7 Converting Blocks | FC | 91 | REG_SCHW | S5_CNVRT | Bi-directional shift register, wordwise |
S5-S7 Converting Blocks | FC | 92 | REG_FIFO | S5_CNVRT | Buffer memory (FIFO) |
S5-S7 Converting Blocks | FC | 93 | REG_LIFO | S5_CNVRT | Stack register (LIFO) |
S5-S7 Converting Blocks | FC | 94 | DB_COPY1 | S5_CNVRT | Copy data block, direct assignment of parameters |
S5-S7 Converting Blocks | FC | 95 | DB_COPY2 | S5_CNVRT | Copy data block, indirect assignment of parameterization |
S5-S7 Converting Blocks | FC | 96 | RETTEN | S5_CNVRT | Save scratchpad memory |
S5-S7 Converting Blocks | FC | 97 | LADEN | S5_CNVRT | Load scratchpad memory |
S5-S7 Converting Blocks | FC | 98 | COD_B8 | S5_CNVRT | Change BCD number to 32 bit dual number |
S5-S7 Converting Blocks | FC | 99 | COD_32 | S5_CNVRT | Change 32 bit dual number to BCD number |
S5-S7 Converting Blocks | FC | 100 | AE_460_1 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 101 | AE_460_2 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 102 | AE_463_1 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 103 | AE_463_2 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 104 | AE_464_1 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 105 | AE_464_2 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 106 | AE_466_1 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 107 | AE_466_2 | S5_CNVRT | Read analog value |
S5-S7 Converting Blocks | FC | 108 | RLG_AA1 | S5_CNVRT | Output analog value |
S5-S7 Converting Blocks | FC | 109 | RLG_AA2 | S5_CNVRT | Output analog value |
S5-S7 Converting Blocks | FC | 110 | PER_ET1 | S5_CNVRT | Read and Write for extended periphery (direct assignment of parameters) |
S5-S7 Converting Blocks | FC | 111 | PER_ET2 | S5_CNVRT | Read and Write for extended periphery (indirect assignment of parameters) |
S5-S7 Converting Blocks | FC | 112 | SINUS | S5_CNVRT | Sine (x) |
S5-S7 Converting Blocks | FC | 113 | COSINUS | S5_CNVRT | Cosine (x) |
S5-S7 Converting Blocks | FC | 114 | TANGENS | S5_CNVRT | Tangent (x) |
S5-S7 Converting Blocks | FC | 115 | COTANG | S5_CNVRT | Cotangent (x) |
S5-S7 Converting Blocks | FC | 116 | ARCSIN | S5_CNVRT | Arc sine (x) |
S5-S7 Converting Blocks | FC | 117 | ARCCOS | S5_CNVRT | Arc cosine (x) |
S5-S7 Converting Blocks | FC | 118 | ARCTAN | S5_CNVRT | Arc tangent (x) |
S5-S7 Converting Blocks | FC | 119 | ARCCOT | S5_CNVRT | Arc cotangens (x) |
S5-S7 Converting Blocks | FC | 120 | LN_X | S5_CNVRT | Natural logarithm ln (x) |
S5-S7 Converting Blocks | FC | 121 | LG_X | S5_CNVRT | Decade logarithm Iog (x) |
S5-S7 Converting Blocks | FC | 122 | B_LOG_X | S5_CNVRT | General logarithm Iog (x) to basis b |
S5-S7 Converting Blocks | FC | 123 | E_H_N | S5_CNVRT | e to the power of n |
S5-S7 Converting Blocks | FC | 124 | ZEHN_H_N | S5_CNVRT | 10 to the power of n |
S5-S7 Converting Blocks | FC | 125 | A2_H_A1 | S5_CNVRT | AKKU 2 to the power of AKKU 1 |
IEC Function Blocks | FC | 1 | AD_DT_TM | IEC | Point Math Add duration to a time |
IEC Function Blocks | FC | 2 | CONCAT | IEC | Combine two STRING variables |
IEC Function Blocks | FC | 3 | D_TOD_DT | IEC | Combine DATE and TIME_OF_DAY to DT |
IEC Function Blocks | FC | 4 | DELETE | IEC | Delete in a STRING variable |
IEC Function Blocks | FC | 5 | DI_STRNG | IEC | Data type conversion DINT to STRING |
IEC Function Blocks | FC | 6 | DT_DATE | IEC | Extract the DATE from DT |
IEC Function Blocks | FC | 7 | DT_DAY | IEC | Extract the day of the week from DT |
IEC Function Blocks | FC | 8 | DT_TOD | IEC | Extract the TIME_OF_DAY from DT |
IEC Function Blocks | FC | 9 | EQ_DT | IEC | Compare DT for equal |
IEC Function Blocks | FC | 10 | EQ_STRNG | IEC | Compare STRING for equal |
IEC Function Blocks | FC | 11 | FIND | IEC | Find in a STRING variable |
IEC Function Blocks | FC | 12 | GE_DT | IEC | Compare DT for greater than or equal |
IEC Function Blocks | FC | 13 | GE_STRNG | IEC | Compare STRING for greater than or equal |
IEC Function Blocks | FC | 14 | GT_DT | IEC | Compare DT for greater than |
IEC Function Blocks | FC | 15 | GT_STRNG | IEC | Compare STRING for greater than |
IEC Function Blocks | FC | 16 | I_STRNG | IEC | Data type conversion INT to STRING |
IEC Function Blocks | FC | 17 | INSERT | IEC | Insert in a STRING variable |
IEC Function Blocks | FC | 18 | LE_DT | IEC | Compare DT for smaller than or equal |
IEC Function Blocks | FC | 19 | LE_STRNG | IEC | Compare STRING for smaller than or equal |
IEC Function Blocks | FC | 20 | LEFT | IEC | Left part of a STRING variable |
IEC Function Blocks | FC | 21 | LEN | IEC | Length of a STRING variable |
IEC Function Blocks | FC | 22 | LIMIT | IEC | Point Math Limit |
IEC Function Blocks | FC | 23 | LT_DT | IEC | Compare DT for smaller than |
IEC Function Blocks | FC | 24 | LT_STRNG | IEC | Compare STRING for smaller than |
IEC Function Blocks | FC | 25 | MAX | IEC | Point Math Select maximum |
IEC Function Blocks | FC | 26 | MID | IEC | Middle part of a STRING variable |
IEC Function Blocks | FC | 27 | MIN | IEC | Point Math Select minimum |
IEC Function Blocks | FC | 28 | NE_DT | IEC | Compare DT for unequal |
IEC Function Blocks | FC | 29 | NE_STRNG | IEC | Compare STRING for unequal |
IEC Function Blocks | FC | 30 | R_STRNG | IEC | Data type conversion REAL to STRING |
IEC Function Blocks | FC | 31 | REPLACE | IEC | Replace in a STRING variable |
IEC Function Blocks | FC | 32 | RIGHT | IEC | Right part of a STRING variable |
IEC Function Blocks | FC | 33 | S5TI_TIM | IEC | Data type conversion S5TIME to TIME |
IEC Function Blocks | FC | 34 | SB_DT_DT | IEC | Point Math Subtract two time values |
IEC Function Blocks | FC | 35 | SB_DT_TM | IEC | Point Math Subtract duration from a time |
IEC Function Blocks | FC | 36 | SEL | IEC | Point Math Binary selection |
IEC Function Blocks | FC | 37 | STRNG_DI | IEC | Data type conversion STRING to DINT |
IEC Function Blocks | FC | 38 | STRNG_I | IEC | Data type conversion STRING to INT |
IEC Function Blocks | FC | 39 | STRNG_R | IEC | Data type conversion STRING to REAL |
IEC Function Blocks | FC | 40 | TIM_S5TI | IEC | Data type conversion TIME to S5TIME |
PID Control Blocks | FB | 41 | CONT_C | ICONT | Continuous Control |
PID Control Blocks | FB | 42 | CONT_S | ICONT | Step Control |
PID Control Blocks | FB | 43 | PULSEGEN | ICONT | Pulse Generation |
PID Control Blocks | FB | 58 | TCONT_CP | CONTROL | Temperature Continuous Controller |
PID Control Blocks | FB | 59 | TCONT_S | CONTROL | Temperature Step Controller |
SIMATIC_NET_CP | FB | 2 | IDENTIFY | CP_300 | For checking device properties |
SIMATIC_NET_CP | FB | 3 | READ | CP_300 | Reads data from a data area of the communication partner specified by a name or index depending on the assignment of parameters for the job. |
SIMATIC_NET_CP | FB | 4 | REPORT | CP_300 | Allows unconfirmed transmission of variables by an FMS server. |
SIMATIC_NET_CP | FB | 5 | STATUS | CP_300 | allows status information to be requested from the communications partner on the specified FMS connection. |
SIMATIC_NET_CP | FB | 6 | WRITE | CP_300 | Transfers data from a specified local data area to a data area on the communication partner. |
Communication Blocks | FB | 8 | USEND | CP_300 | Uncoordinated Sending of Data |
Communication Blocks | FB | 9 | URCV | CP_300 | Uncoordinated Receiving of Data |
Communication Blocks | FB | 12 | BSEND | CP_300 | Sending Segmented Data |
Communication Blocks | FB | 13 | BRCV | CP_300 | Receiving Segmented Data |
Communication Blocks | FB | 14 | GET | CP_300 | Read Data from a Remote CPU |
Communication Blocks | FB | 15 | PUT | CP_300 | Write Data to a Remote CPU |
Communication Blocks | FB | 20 | GETIO | IO_FUNCT | Read All Inputs of a DP Standard Slave/PROFINET IO Device |
Communication Blocks | FB | 21 | SETIO | IO_FUNCT | Write All Outputs of a DP Standard Slave/PROFINET IO Device |
Communication Blocks | FB | 22 | GETIO_PART | IO_FUNCT | Read a Part of the Inputs of a DP Standard Slave/PROFINET IO Device |
Communication Blocks | FB | 23 | SETIO_PART | IO_FUNCT | Write a Part of the Outputs of a DP Standard Slave/PROFINET IO Device |
FB | 55 | IP_CONFIG | CP_300 | Transfers a configuration data block (CONF_DB) containing connection data for an Ethernet CP. | |
Communication Blocks | FB | 63 | TSEND | COMM | Sending Data via TCP native and ISO on TCP |
Communication Blocks | FB | 64 | TRCV | COMM | Receiving Data via TCP native and ISO on TCP |
Communication Blocks | FB | 65 | TCON | COMM | Establishing a Connection using TCP native and ISO on TCP |
Communication Blocks | FB | 66 | TDISCON | COMM | Terminating a Connection using TCP native and ISO on TCP |
Communication Blocks | FB | 67 | TUSEND | COMM | Sending Data via UDP |
Communication Blocks | FB | 68 | TURCV | COMM | Receiving Data via UDP |
Communication Blocks | FC | 1 | DP_SEND | CP_300 | transfers data to the PROFIBUS CP |
Communication Blocks | FC | 2 | DP_RECV | CP_300 | receives data on PROFIBUS |
Communication Blocks | FC | 3 | DP_DIAG | CP_300 | used to request diagnostic information |
Communication Blocks | FC | 4 | DP_CTRL | CP_300 | transfers control jobs to the PROFIBUS CP |
SIMATIC_NET_CP | FC | 5 | AG_SEND | CP_300 | data by means of a configured connection to the communication partner (<= 240 bytes). |
SIMATIC_NET_CP | FC | 6 | AG_RECV | CP_300 | data by means of a configured connection from the communication partner (<= 240 bytes, not email). |
SIMATIC_NET_CP | FC | 7 | AG_LOCK | CP_300 | the external data access by means of FETCH/WRITE (not for UDP, email). |
SIMATIC_NET_CP | FC | 8 | AG_UNLOCK | CP_300 | the external data access by means of FETCH/WRITE (not for UDP, email). |
SIMATIC_NET_CP | FC | 10 | AG_CNTRL | CP_300 | allows you to diagnose connections. When necessary, you can reinitialize connection establishment using the FC. |
SIMATIC_NET_CP | FC | 11 | PNIO_SEND | CP_300 | used for data transfer in the CP modes PROFINET IO controller or PROFINET IO device. |
SIMATIC_NET_CP | FC | 12 | PNIO_RECV | CP_300 | used to receive data in the CP modes PROFINET IO controller or PROFINET IO device. |
SIMATIC_NET_CP | FC | 40 | FTP_CONNECT | CP_300 | Establish an FTP connection |
SIMATIC_NET_CP | FC | 41 | FTP_STORE | CP_300 | Store a file on the FTP server |
SIMATIC_NET_CP | FC | 42 | FTP_RETRIEVE | CP_300 | Retrieve a file from the FTP server |
SIMATIC_NET_CP | FC | 43 | FTP_DELETE | CP_300 | Delete a file on the FTP server |
SIMATIC_NET_CP | FC | 44 | FTP_QUIT | CP_300 | Enable an FTP connection |
SIMATIC_NET_CP | FC | 50 | AG_LSEND | CP_300 | data by means of a configured connection to the communication partner. |
SIMATIC_NET_CP | FC | 60 | AG_LRECV | CP_300 | data by means of a configured connection from the communication partner (not email). |
Communication Blocks | FC | 62 | C_CNTRL | CP_300 | Query a connection status for S7-300 |
TI-S7 Converting Blocks | FB | 80 | LEAD_LAG | CONVERT | Lead/Lag Algorithm |
TI-S7 Converting Blocks | FB | 81 | DCAT | TIMERS | Discrete Control Alarm Timer |
TI-S7 Converting Blocks | FB | 82 | MCAT | TIMERS | Motor Control Alarm Timer |
TI-S7 Converting Blocks | FB | 83 | IMC | COMPARE | Index Matrix Compare |
TI-S7 Converting Blocks | FB | 84 | SMC | COMPARE | Scan Matrix Compare |
TI-S7 Converting Blocks | FB | 85 | DRUM | TIMERS | Event Maskable Drum |
TI-S7 Converting Blocks | FB | 86 | PACK | MOVE | Pack Data |
TI-S7 Converting Blocks | FC | 80 | TONR | TIMERS | Software Timer On Delay—Retentive |
TI-S7 Converting Blocks | FC | 81 | IBLKMOV | MOVE | Indirect Block Move |
TI-S7 Converting Blocks | FC | 82 | RSET | BIT_LOGC | Reset Range of Outputs |
TI-S7 Converting Blocks | FC | 83 | SET | BIT_LOGC | Set Range of Outputs |
TI-S7 Converting Blocks | FC | 84 | ATT | TABLE | Add to Table |
TI-S7 Converting Blocks | FC | 85 | FIFO | TABLE | First In/First Out Unload Table |
TI-S7 Converting Blocks | FC | 86 | TBL_FIND | TABLE | Table Find |
TI-S7 Converting Blocks | FC | 87 | LIFO | TABLE | Last In/First Out Unload Table |
TI-S7 Converting Blocks | FC | 88 | TBL | TABLE | Table |
TI-S7 Converting Blocks | FC | 89 | TBL_WRD | TABLE | Move Table to Word |
TI-S7 Converting Blocks | FC | 90 | WSR | SHIFT | Word Shift Register |
TI-S7 Converting Blocks | FC | 91 | WRD_TBL | TABLE | Word to Table |
TI-S7 Converting Blocks | FC | 92 | SHRB | SHIFT | Bit Shift Register |
TI-S7 Converting Blocks | FC | 93 | SEG | CONVERT | Seven Segment Decoder |
TI-S7 Converting Blocks | FC | 94 | ATH | CONVERT | ASCII to Hex |
TI-S7 Converting Blocks | FC | 95 | HTA | CONVERT | Hex to ASCII |
TI-S7 Converting Blocks | FC | 96 | ENCO | CONVERT | Encode Binary Position |
TI-S7 Converting Blocks | FC | 97 | DECO | CONVERT | Decode Binary Position |
TI-S7 Converting Blocks | FC | 98 | BCDCPL | CONVERT | Ten’s Complement |
TI-S7 Converting Blocks | FC | 99 | BITSUM | CONVERT | Sum Number of Bits |
TI-S7 Converting Blocks | FC | 100 | RSETI | BIT_LOGC | Reset Range of Immediate Outputs |
TI-S7 Converting Blocks | FC | 101 | SETI | BIT_LOGC | Set Range of Immediate Outputs |
TI-S7 Converting Blocks | FC | 102 | DEV | MATH_FP | Standard Deviation |
TI-S7 Converting Blocks | FC | 103 | CDT | TABLE | Correlated Data Table |
TI-S7 Converting Blocks | FC | 104 | TBL_TBL | TABLE | Table to Table |
TI-S7 Converting Blocks | FC | 105 | SCALE | CONVERT | Scaling Values |
TI-S7 Converting Blocks | FC | 106 | UNSCALE | CONVERT | Unscaling Values |
Miscellaneous Blocks | FB | 60 | SET_SW | TIMEFUNC | supports the summertime/wintertime changeover in CPUs that do not have the time status. For this purpose it sets the CPU clock to the current time and according to the changeover rules in the Control DB. |
Miscellaneous Blocks | FB | 61 | SET_SW_S | TIMEFUNC | supports the summertime/wintertime changeover in CPUs that do have the time status. For this purpose it sets the time status to the current time and according to the changeover rules in the Control DB. |
Miscellaneous Blocks | FB | 62 | TIMESTMP | TIMEFUNC | transfers the time-stamped messages of an IM153-2 into its instance DB. |
Miscellaneous Blocks | FC | 60 | LOC_TIME | TIMEFUNC | reads the time status or time of the CPU and calculates the local time. It is therefore only useful on CPUs with time status. |
Miscellaneous Blocks | FC | 61 | BT_LT | TIMEFUNC | calculates the local time from the base time given at the input. |
Miscellaneous Blocks | FC | 62 | LT_BT | TIMEFUNC | calculates the base time from the local time given at the input. |
Miscellaneous Blocks | FC | 63 | S_LTINT | TIMEFUNC | sets the required time interrupt to the preset time. This time is given in local time. |